Accreditation & Awards

  • Internal Arcing-Fault Type Test (Annex ZD)

    1. 50KA rms at 415V Outgoing 250A MCCB Schneider Vertical/Horizontal Module (Test Report No. 103469)
    2. 50KA rms at 415V Outgoing 630A MCCB Schneider Vertical/Horizontal Module (Test Report No. 103469)
    3. 50KA rms at 415V Outgoing 1000A MCCB Schneider Vertical Module (Test Report No. 103469)
    4. 50KA rms at 415V Outgoing 250A MCCB Terasaki Vertical/Horizontal Module (Test Report No. 103470)
    5. 50KA rms at 415V Outgoing 400A MCCB Terasaki Horizontal Module (Test Report No. 103470)
    6. 50KA rms at 415V Outgoing 630A MCCB Terasaki Vertical/Horizontal Module (Test Report No. 103470)
    7. 50KA rms at 415V Outgoing 1250A MCCB Terasaki Vertical Module (Test Report No. 103470)
    8. 70KA rms at 415V 250A MCCB Compartment of a 4000A, 415V/415V, 50 Hz, switchgear and controlgear assembly (Test Report No. 103528)
    9. 70KA rms at 415V 400A MCCB Compartment of a 4000A, 415V/415V, 50 Hz, switchgear and controlgear assembly (Test Report No. 103528)
    10. 70KA rms at 415V 630A MCCB Compartment of a 4000A, 415V/415V, 50 Hz, switchgear and controlgear assembly (Test Report No. 103528)
    11. 70KA rms at 415V 250A MCCB Compartment of a 5000A, 415V/415V, 50 Hz, switchgear and controlgear assembly (Test Report No. 103528)
    12. 70KA rms at 415V 400A MCCB Compartment of a 5000A, 415V/415V, 50 Hz, switchgear and controlgear assembly (Test Report No. 103528)
    13. 70KA rms at 415V 630A MCCB Compartment of a 5000A, 415V/415V, 50 Hz, switchgear and controlgear assembly (Test Report No. 103528)

  • Temperature Rise Type Tests

    1. Verification of Temperature Rise limits for 4000A, 415V 50Hz, switchgear and controlgear assembly (Test Report No. 103518A)
    2. Verification of Temperature Rise limits for 5000A, 415V 50Hz switchgear and controlgear assembly (Test Report No. 103521)

  • Short Circuit Type Tests

    1. 1600A 415V/690V, 50Hz, Three-phase main vertical/horizontal neutral busbar of a switchgear and controlgear assembly for 63KA for 1sec (Test Report No. 101566)
    2. 1600A 415V/690V, 50Hz, Three-phase and neutral main horizontal busbars of a switchgear and controlgear assembly for 63KA for 1sec (Test Report No. 101565)
    3. 4000A, 415V, 50Hz, main horizontal busbar short-circuit withstand test 36KA rms for 1sec (Test Report No.103529A)
    4. 4000A, 415V, 50Hz, vertical phase busbar short-circuit withstand test 36KA rms for 1sec (Test Report No.103529A)
    5. 3500A, 415V, 50Hz, horizontal phase busbar short-circuit withstand test 63KA rms for 1sec (Test Report No.1368/1)
    6. 3500A, 415V, 50Hz, horizontal phase busbar short-circuit withstand test 80KA rms for 1sec (Test Report No.1368/2)
    7. 6300A 415V/690V, 50Hz, Three-phase horizontal and neutral busbars of a switchgear and controlgear assembly for 100KA for 1sec (Test Report No. 102642)
    8. 6300A 415V/690V, 50Hz, Three-phase horizontal and neutral busbars of a switchgear and controlgear assembly for 100KA for 3sec (Test Report No. 102642)

  • IP Code - Degrees of Protection Provided by Enclosures

    1. IP56 – Limited ingress of dust permitted (no harmful deposit) and protected against strong jets of water. (Report No. 0125PRIPT56_529)
    2. IP66 – Totally protected against the ingress of dust and protected against strong jets of water. (Report No. 2611PRIPT66_529)